I found that the UM2, barely reaching 5 mm3/s, was set to 12 mm3/s for PLA, so I checked various settings and corrected them:

ABS from 2 to 4.5 mm3/s (tested myself on Cura, it's the standard settings)
PLA from 12 to 5 (tested myself)

I changed one flow multiplier for ABS because it was too low (my experience on multiple ABS on the UM2, using Cura).

And I increased the bed temperature for ABS from 80C to 90C.

Tests

I used my experience with UM2 and Cura.

Copy link
Owner

@SoftFever SoftFever left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Thank you!