Flow rate sensor is slow and not accurate at low flows #26

Open
hallboyone opened this issue Jul 11, 2023 · 1 comment
Open

Flow rate sensor is slow and not accurate at low flows #26

hallboyone opened this issue Jul 11, 2023 · 1 comment
Labels
bug Something isn't working hardware Circuit and wiring issues
Milestone

Comments

@hallboyone
Copy link
Owner

It could be replaced with something like this. However, this will require retuning everything, but this is probably okay since the flow control never worked great anyway.

@hallboyone hallboyone added this to the Release 1.0 milestone Jul 11, 2023
@hallboyone hallboyone added bug Something isn't working hardware Circuit and wiring issues labels Jul 11, 2023
@hallboyone
Copy link
Owner Author

hallboyone commented Jul 12, 2023

I'm testing a new sensor (linked above) and have collected the following data.
Screenshot 2023-07-12 at 5 15 19 PM
The slope of the trend line is the conversion between the pulses and volume. The exact values to 6 decimal places are

slope     =  0.009472
intercept = -0.054317

At low flows, the measurements get pretty noisy, but it should be good enough. As an added benefit, the pulses are much more frequent (about 60Hz at 0.5ml/s) so the discrete derivative will be able to update much faster.